Click Open log CSV or drop a log CSV anywhere on this page. The track map and all the graphs appear once a log is loaded.
Drag the map to move the image under the track. Use the sliders to match the scale and rotation, then save.
Each event is numbered on the map and graphs with a pink diamond at its peak reading. Click a row to zoom to it. Seconds are estimated from the reading's place in its logged minute.
| # | When | Type | 1-s RMS, m/s² | a-Peak, m/s² | Crest | v-RMS, mm/s | Speed, km/h | Level | ISO 2631-1 reference |
|---|
Indicative only, not a compliance measurement. The ifm VMB301 values are unweighted (1 to 7,500 Hz, all three axes combined) and taken under the seat, while ISO 2631-1 uses frequency-weighted seat acceleration (Wk vertical, Wd horizontal). Raw log values are converted with the sensor's resolution: acceleration 1 count = 0.01 m/s², velocity 0.1 mm/s, crest 0.1. Action and limit values: 0.5 and 1.15 m/s² A(8); VDV 9.1 and 21 m/s1.75 (EU Directive 2002/44/EC). ISO 2631-1 health guidance caution zone for 8 h: 0.45 to 0.9 m/s². eVDV = 1.4 × aeq × t¼. ISO/TR 25398 gives typical values per machine type; enter the one for this machine to compare.
Set the machine for each day. Days with the same machine are compared together; a day you leave out is dropped from the map, the graphs, the event list and the comparison.
| Day | Logged | Readings | Machine | Leave out |
|---|
| Machine | Pass | Started | Time | Covered | Mean speed, km/h | aeq, m/s² | Highest a-Peak, m/s² | Highest crest | Mean v-RMS, mm/s |
|---|
No snippets yet. Go to Full log, mark a start and end on the timeline and click Add snippet.